Manufacturer | Device | Device type | Communication type | Communication protocol | Data reception | Data writing |
---|---|---|---|---|---|---|
Elgas | Datcom | Data logger | Pull | Native Elgas | Current values, data archive, device parameters | Time synchronization |
Elgas | Datcom (2020) | Data logger | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows, service windows |
Elgas | Datcom 2 | Data logger | Pull | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows |
Elgas | Datcom AMR | Data logger | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows |
Elgas | Datcom Lite | Data logger | Pull/Push/NB IoT | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows, service windows |
Elgas | Datcom Plus | Data logger | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows, service windows |
Elgas | Elcor | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows, service windows |
Elgas | Elcor 2 | EVC | Pull | Elgas II/Modbus | Current values, data archives, device parameters | Time synchronization |
Elgas | Elcor 94 | EVC | Pull | Native Elgas | Current values, data archives, device parameters | Time synchronization |
Elgas | Elcor Lite | EVC | Pull/Push/NB IoT | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows, service windows |
Elgas | Elcor Plus | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows, service windows |
Elgas | Maxi Datcom | Data logger | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows |
Elgas | Maxi Elcor | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows |
Elgas | Micro Elcor | EVC | Pull | Native Elgas | Current values, data archive, device parameters | Time synchronization |
Elgas | Micro Elcor 2 | EVC | Pull | Native Elgas | Current values, data archive, device parameters | Time synchronization |
Elgas | Midi Datcom | Data logger | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows |
Elgas | Midi Elcor | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows |
Elgas | Mini Datcom | Data logger | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows |
Elgas | Mini Elcor | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows |
Elgas | Nano Elcor | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows |
Elgas | Pico Datcom | Data logger | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, setup), device parameters | Time synchronization, communication parameters (IP address and port), call windows |
Elgas | Pico Elcor | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows |
Elgas | Pico Elcor 2 | EVC | Pull/Push | Elgas II/Modbus | Current values, archives (data, daily, binary, gas composition, setup), device parameters | Time synchronization, gas composition, communication parameters (IP address and port), call windows, service windows |
Elster | EK 84 | EVC | Pull | Native | Current values, archives (data) | – |
Elster | EK 86 | EVC | Pull | Native | Current values, archives (data) | – |
Elster | EK 88 | EVC | Pull | Native | Current values, archives (data) | – |
Elster | EK 220 | EVC | Pull | Native | Current values, archives (data) | Time synchronization |
Elster | EK 260 | EVC | Pull | Native | Current values, archives (data) | Time synchronization |
Elster | EK 280 | EVC | Pull | Native | Current values, archives (data) | Time synchronization |
Elster | M2000 | Flow computer | Pull | Native | Current values, archives (data) | – |
PLUM | MacBAT5 | EVC | Pull/Push | Gazmodem | Current values, archives (Data, Daily, gas composition), device parameters | Time synchronization, gas composition |
PLUM | MacMat Iie | Flow computer | Pull | Gazmodem | Current values, archives (data) | – |
PLUM | MacMat IV | Flow computer | Pull | Gazmodem | Current values, archives (data) | – |
PLUM | MacR6 | Data logger | Push + Payloads | Gazmodem | Current values, archives (data), device parameters | Time synchronization |
PLUM | MacR6IoT | Data logger | Push + Payloads/GPRS/NB IoT | Gazmodem | Current values, archives (data), device parameters | Time synchronization |
PLUM | MacR6N | Data logger | Push + Payloads | Gazmodem | Current values, archives (data), device parameters | Time synchronization |
PLUM | MacR6P | Data logger | Push + Payloads | Gazmodem | Current values, archives (data), device parameters | Time synchronization |
PLUM | MacR6Z0P | Data logger | Push + Payloads | Gazmodem | Current values, archives (data), device parameters | Time synchronization |
Itron | Corus | EVC | Pull | Native | Current values, archives (data) | Time synchronization |
Common | CMK02 | EVC | Pull | Native | Current values, archives (data) | Time synchronization |
Emerson | Solartron | Flow computer | Pull | Native Solartron | Current values, archives (data) | – |
Emerson | FloBoss 600 | Flow computer | Pull | Modbus/HTTP | Current values, archives (data) | – |
Emerson | FloBoss 1200 | Flow computer | Pull | DNP 3 | Current values, archives (data) | – |
Emerson | Daniel 2350 | Chromatograph | Pull | Native | Current values, archives (hourly, daily) | – |
Emerson | Daniel 2350A | Chromatograph | Pull | Native | Current values, archives (hourly, daily) | – |
Emerson | Daniel 700 | Chromatograph | Pull | Native | Current values, archives (hourly, daily) – only using FTP | – |
ODS | Omni 3000 | Flow computer | Pull | Native | Current values, archives (data) | – |
Pietro Fiorentini | Genius Slim | EVC/Datalogger | Pull/Push | DLMS | Current values, archives (data) | – |
SICK | Flowsic 500 | Ultrasonic gas meter | Pull | Native | Current values, archives (data) | – |
Manufacturer | Device | Device type | Communication type | Communication protocol | Data reception | Data writing |
---|---|---|---|---|---|---|
AMT | AMT B2C | Electricity meter | Pull | DLMS for electricity meters | Current values, archives (hourly, daily) | – |
Landis Gyr | E650 | Electricity meter | Pull | DLMS for electricity meters | Current values, archives (hourly, daily) | – |
Schneider Electric | IEM 3000 | Electricity meter | Pull | Native M-Bus | Current values | – |
Manufacturer | Device | Device type | Communication type | Communication protocol | Data reception | Data writing |
---|---|---|---|---|---|---|
AEM | G4EUS2 | Smart Gas Meter | Push | DLMS COSEM – GPRS | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Honeywell | Honeywell EI7 | Smart Gas Meter | Push/CF48 | DLMS COSEM – NB IoT TCP | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Honeywell Elster | ElsterBKG4 | Smart Gas Meter | Push | DLMS COSEM – GPRS | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Meter Italia | Meter EG4EVO | Smart Gas Meter | Push | DLMS COSEM – GPRS | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
MeterRSit | MeteRSit G | Smart Gas Meter | Push | DLMS COSEM – GPRS | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Metrix | MetrixWTG4SG | Smart Gas Meter | Push | DLMS COSEM – GPRS | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Pietro Fiorentini | Fiorentini RSE | Smart Gas Meter | Push | DLMS COSEM – GPRS | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Pietro Fiorentini | Fiorentini RSE IoT | Smart Gas Meter | Push/CF48, CF18 | DLMS COSEM – NB IoT UDP | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
SAGEMCOM | SAGEMCOM | Smart Gas Meter | Push/CF48 | DLMS COSEM – NB IoT UDP | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Shitek | UGMG4 | Smart Gas Meter | Push | DLMS COSEM – GPRS | Current values, valve state, battery, daily archives, device status, device parameters | Time synchronization, communication parameters (IP, port), valve control, parameters – close valve after manipulation, close valve on weekends |
Manufacturer | Device | Device type | Communication type | Communication protocol | Data reception | Data writing |
---|---|---|---|---|---|---|
Ctr | – | – | Push/Pull | – | Current values, archive values, device parameters – customizable | Customizable |
DLMS/COSEM | – | – | Push/Pull | – | Current values, archive values, device parameters – customizable | Customizable |
M-Bus | – | – | Pull | – | Current values (electricity meters, water meters, heating and cooling meters, gas meters) | – |
Modbus | – | – | Pull | – | Current values, archive values, device parameters – customizable | Customizable |